Ordering no:
Female panel mount connector IP 67, shielded
Female panel mount connector IP 67, shielded, Series 430
Available numbers of contacts
09 4908 00 03
Push-Pull female panel mount connector, Contacts: 3, shieldable, solder, IP67
Push-Pull, series 430, Subminiature connectors
Order number |
09 4908 00 03
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 2 |
Overvoltage category | I |
Insulating material group | II |
Volume resistivity | ≤ 5 mΩ |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT, PA |
Customs tariff number | 85369010 |
Weight (g) | 9.942 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4912 00 04
Push-Pull female panel mount connector, Contacts: 4, shieldable, solder, IP67
Push-Pull, series 430, Subminiature connectors
Order number |
09 4912 00 04
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 2 |
Overvoltage category | I |
Insulating material group | II |
Volume resistivity | ≤ 5 mΩ |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT, PA |
Customs tariff number | 85369010 |
Weight (g) | 10.022 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4916 00 05
Push-Pull female panel mount connector, Contacts: 5, shieldable, solder, IP67
Push-Pull, series 430, Subminiature connectors
Order number |
09 4916 00 05
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,25 mm² |
Wire gauge (AWG) | 24 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 2 |
Overvoltage category | I |
Insulating material group | II |
Volume resistivity | ≤ 5 mΩ |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT, PA |
Customs tariff number | 85369010 |
Weight (g) | 10.137 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4928 00 07
Push-Pull female panel mount connector, Contacts: 7, shieldable, solder, IP67
Push-Pull, series 430, Subminiature connectors
Order number |
09 4928 00 07
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,14 mm² |
Wire gauge (AWG) | 26 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 2 |
Overvoltage category | I |
Insulating material group | II |
Volume resistivity | ≤ 5 mΩ |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT, PA |
Customs tariff number | 85369010 |
Weight (g) | 9.989 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 4932 00 08
Push-Pull female panel mount connector, Contacts: 8, shieldable, solder, IP67
Push-Pull, series 430, Subminiature connectors
Order number |
09 4932 00 08
|
Connector locking system | Push-Pull |
Termination | solder |
Wire gauge (mm) | 0,14 mm² |
Wire gauge (AWG) | 26 |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 2 |
Overvoltage category | I |
Insulating material group | II |
Volume resistivity | ≤ 5 mΩ |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT, PA |
Customs tariff number | 85369010 |
Weight (g) | 10.041 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Contact to customer service