Ordering no:
Female panel mount connector, dip-solder, screwed from front
Female panel mount connector, dip-solder, screwed from front, Series 712/702
Available numbers of contacts
09 0404 90 02
M9 IP67 female panel mount connector, Contacts: 2, shieldable, dip-solder, IP67
M9, series 712, Subminiature connectors
Order number |
09 0404 90 02
|
Connector locking system | bolted |
Termination | dip-solder |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 5.158 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 0408 90 03
M9 IP67 female panel mount connector, Contacts: 3, shieldable, dip-solder, IP67
M9, series 712, Subminiature connectors
Order number |
09 0408 90 03
|
Connector locking system | bolted |
Termination | dip-solder |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 5.242 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 0412 90 04
M9 IP67 female panel mount connector, Contacts: 4, shieldable, dip-solder, IP67
M9, series 712, Subminiature connectors
Order number |
09 0412 90 04
|
Connector locking system | bolted |
Termination | dip-solder |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 5 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 0416 90 05
M9 IP67 female panel mount connector, Contacts: 5, shieldable, dip-solder, IP67
M9, series 712, Subminiature connectors
Order number |
09 0416 90 05
|
Connector locking system | bolted |
Termination | dip-solder |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 5.379 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 0424 90 07
M9 IP67 female panel mount connector, Contacts: 7, shieldable, dip-solder, IP67
M9, series 712, Subminiature connectors
Order number |
09 0424 90 07
|
Connector locking system | bolted |
Termination | dip-solder |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 5.3 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
09 0428 90 08
M9 IP67 female panel mount connector, Contacts: 8, shieldable, dip-solder, IP67
M9, series 712, Subminiature connectors
Order number |
09 0428 90 08
|
Connector locking system | bolted |
Termination | dip-solder |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 5.351 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?