Ordering no:
Female cable connector overmoulded, unshielded
Female cable connector overmoulded, unshielded, Series 702
Available numbers of contacts
79 1452 212 03
M9 IP67 female cable connector, Contacts: 3, not shielded, moulded on cable, IP67, Standard cable, PUR black, 3 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1452 212 03
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 2 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 32 x 0,1 mm |
Cable diameter | 4.5 |
Conductor resistance | 72Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 22 mm |
Bending radius, moving cable | Min. 45 mm |
Customs tariff number | 85444290 |
Weight (g) | 58.5 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1452 215 03
M9 IP67 female cable connector, Contacts: 3, not shielded, moulded on cable, IP67, Standard cable, PUR black, 3 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1452 215 03
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 5 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 32 x 0,1 mm |
Cable diameter | 4.5 |
Conductor resistance | 72Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 22 mm |
Bending radius, moving cable | Min. 45 mm |
Customs tariff number | 85444290 |
Weight (g) | 135 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1456 212 05
M9 IP67 female cable connector, Contacts: 5, not shielded, moulded on cable, IP67, Standard cable, PUR black, 5 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1456 212 05
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 2 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 32 x 0,1 mm |
Cable diameter | 5.0 |
Conductor resistance | 72Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 25 mm |
Bending radius, moving cable | Min.50 mm |
Customs tariff number | 85444290 |
Weight (g) | 75.5 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1456 215 05
M9 IP67 female cable connector, Contacts: 5, not shielded, moulded on cable, IP67, Standard cable, PUR black, 5 x 0,25 mm²
M9, series 702, Subminiature connectors
Order number |
79 1456 215 05
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable length | 5 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 32 x 0,1 mm |
Cable diameter | 5.0 |
Conductor resistance | 72Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 25 mm |
Bending radius, moving cable | Min. 50 mm |
Customs tariff number | 85444290 |
Weight (g) | 175.1 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1462 212 08
M9 IP67 female cable connector, Contacts: 8, not shielded, moulded on cable, IP67, Standard cable, PUR black, 8 x 0,14 mm²
M9, series 702, Subminiature connectors
Order number |
79 1462 212 08
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.14 mm² |
Wire gauge (AWG) | 26 |
Cable length | 2 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC/ PE |
Single-lead structure | 18 x 0,10 mm |
Cable diameter | 5.0 |
Conductor resistance | 117Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 25 mm |
Bending radius, moving cable | Min. 50 mm |
Customs tariff number | 85444290 |
Weight (g) | 67.877 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
79 1462 215 08
M9 IP67 female cable connector, Contacts: 8, not shielded, moulded on cable, IP67, Standard cable, PUR black, 8 x 0,14 mm²
M9, series 702, Subminiature connectors
Order number |
79 1462 215 08
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.14 mm² |
Wire gauge (AWG) | 26 |
Cable length | 5 m |
Degree of protection | IP67 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 70 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | PUR |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC/ PE |
Single-lead structure | 18 x 0,10 mm |
Cable diameter | 5.0 |
Conductor resistance | 117Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | Min. 25 mm |
Bending radius, moving cable | Min. 50 mm |
Customs tariff number | 85444290 |
Weight (g) | 160 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).