Ordering no:
Female panel mount connector, solder, screwed from front, 2 - 8 contacts
Female panel mount connector, solder, screwed from front, 2 - 8 contacts, Series 581/ 680/ 682
Available numbers of contacts
09 0304 80 02
M16 IP40 female panel mount connector, Contacts: 2, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0304 80 02
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 8.697 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 0304 89 02
M16 IP40 female panel mount connector, Contacts: 2, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0304 89 02
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 8.697 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 0308 80 03
M16 IP40 female panel mount connector, Contacts: 3 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0308 80 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 8.804 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 0308 89 03
M16 IP40 female panel mount connector, Contacts: 3 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0308 89 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 8.804 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 0312 80 04
M16 IP40 female panel mount connector, Contacts: 4, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0312 80 04
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 9.017 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 0312 89 04
M16 IP40 female panel mount connector, Contacts: 4, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0312 89 04
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 9.017 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 0316 80 05
M16 IP40 female panel mount connector, Contacts: 5, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0316 80 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 9.048 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 0316 89 05
M16 IP40 female panel mount connector, Contacts: 5, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0316 89 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 9.048 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 0320 80 05
M16 IP40 female panel mount connector, Contacts: 5 (stereo), Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0320 80 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 8.69 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
09 0320 89 05
M16 IP40 female panel mount connector, Contacts: 5 (stereo), Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0320 89 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 8.695 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
09 0324 80 06
M16 IP40 female panel mount connector, Contacts: 6 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0324 80 06
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 9.266 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 0324 89 06
M16 IP40 female panel mount connector, Contacts: 6 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0324 89 06
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 9.266 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
09 0328 80 07
M16 IP40 female panel mount connector, Contacts: 7, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0328 80 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 9.41 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
09 0328 89 07
M16 IP40 female panel mount connector, Contacts: 7, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0328 89 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 9.41 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
09 0474 80 08
M16 IP40 female panel mount connector, Contacts: 8 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0474 80 08
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 8.899 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
09 0474 89 08
M16 IP40 female panel mount connector, Contacts: 8 DIN, Shielding is not possible, solder, IP40
M16, series 680, Miniature connectors
Order number |
09 0474 89 08
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 1010Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Housing material | Zinc die-cast nickel-plated |
Customs tariff number | 85369010 |
Weight (g) | 8.907 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?