Ordering no:
Female cable connector with cable clamp, shieldable, cable outlet 6-8 mm
Female cable connector with cable clamp, shieldable, cable outlet 6-8 mm , Series 581
Available numbers of contacts
99 2002 20 02
M16 IP40 female cable connector, Contacts: 2, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2002 20 02
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.237 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2002 29 02
M16 IP40 female cable connector, Contacts: 2, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2002 29 02
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.237 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2006 20 03
M16 IP40 female cable connector, Contacts: 3 DIN, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2006 20 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.361 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2006 29 03
M16 IP40 female cable connector, Contacts: 3 DIN, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2006 29 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 7 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.361 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2010 20 04
M16 IP40 female cable connector, Contacts: 4, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2010 20 04
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.544 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2014 20 05
M16 IP40 female cable connector, Contacts: 5, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2014 20 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.638 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2014 29 05
M16 IP40 female cable connector, Contacts: 5, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2014 29 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.638 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2018 20 05
M16 IP40 female cable connector, Contacts: 5 (stereo), 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2018 20 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 6 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.258 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2022 20 06
M16 IP40 female cable connector, Contacts: 6 DIN, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2022 20 06
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.844 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2022 29 06
M16 IP40 female cable connector, Contacts: 6 DIN, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2022 29 06
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.844 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- The connector is not suitable for mains voltages. Please observe the pollution degrees and the overvoltage category. For further information refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2026 20 07
M16 IP40 female cable connector, Contacts: 7, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2026 20 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.948 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2026 29 07
M16 IP40 female cable connector, Contacts: 7, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2026 29 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 800 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.948 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2062 20 08
M16 IP40 female cable connector, Contacts: 8 DIN, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2062 20 08
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.403 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2062 29 08
M16 IP40 female cable connector, Contacts: 8 DIN, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2062 29 08
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.411 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2030 20 12
M16 IP40 female cable connector, Contacts: 12, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2030 20 12
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.43 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2034 20 14
M16 IP40 female cable connector, Contacts: 14, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2034 20 14
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.548 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
99 2038 20 16
M16 IP40 female cable connector, Contacts: 16, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2038 20 16
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.674 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
99 2042 20 19
M16 IP40 female cable connector, Contacts: 19, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2042 20 19
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | 24 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 3 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.829 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
99 2046 20 24
M16 IP40 female cable connector, Contacts: 24, 6,0 - 8,0 mm, shieldable, solder, IP40
M16, series 581, Miniature connectors
Order number |
99 2046 20 24
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.14 mm² |
Wire gauge (AWG) | 26 |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP40 |
Mechanical operation | > 500 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 1 A |
Rated voltage | 60 V |
Rated impulse voltage | 500 V |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PBT (UL 94 V-0) |
Customs tariff number | 85369010 |
Weight (g) | 31.701 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?